The Model
ASC300KuE-T Beacon Tracking Receiver is a high
performance self-contained unit that is designed to real
time track the power density of a satellite beacon and
output a DC voltage that is linearly proportional to the
beacon power by utilizing a true, RMS-responding power
detector. The ASC300KuE-T
Beacon Receiver will tune over the three primary Ku band
satellites (10.7-11.70 GHz, 11.70 – 12.20 GHz, 12.25 –
12.75 GHz).
 |
Input
Frequency...............................................................10.7
to 12.75 GHz
Internal Block Converter |
 |
Pre-detection
Bandwidth.....................................................60
kHz Standard
Other Bandwidths Available |
 |
Input
Level....................................... -90 dBm, minimum;
-30 dBm, maximum For full tracking range capability |
 |
Frequency
Tuning...................................................................
10 kHz Steps |
 |
Frequency
Adjust................................................... Front
Panel or Remotely |
 |
Frequency
Stability.................................................... <1
ppm, 00c to +500c |
 |
AFC.............................................................................................+
30 kHz |
 |
Threshold....................................................<45
dB-Hz (C/N0) for acquisition |
 |
Input
Impedance.............................................................................
50 Ohm |
 |
Input
Connector............................................Type-N,
Female (SMA Optional) |
 |
Output
Impedance.....................................................100
Ohm, single ended |
 |
Output
Connector..........................................Terminal Plug
and BNC Female |
 |
Tracking
Gradient...........................................................
0.5 V/dB, Standard |
 |
Tracking
Response...................... 0 to +10 VDC for a 20dB input
level change |
 |
System Level
Adjust..........................................................................
60 dB |
 |
Frequency
Reference........................................................
10 MHz (Internal) |
 |
Phase
Noise.................................................... >75
dB-Hz,1kHz from Carrier |
 |
Alarms......................................................................
Unit Lock, LNB Power |
 |
Alarm
Relay....................................................................................
Form-C |
 |
External LNB
Power................................................ No
External LNB Power |
 |
CDS
(Optional)....................RS-232 or RS-422 DB-9
female
connector on rear |
 |
Front Panel
Display.....................................................
Vacuum Fluorescent |
 |
M &
C...................................RS-232 or RS-422/485
Switchable on rear panel |
 |
M & C
Connector.........................................................DB-9,
Female on rear |
 |
Ethernet 10/100 Base
T......................(OPTIONAL)
Not installed on STD unit.
For Ethernet Specifications
CLICK HERE |
 |
Ethernet
Connector.................................................................RJ-45
on rear |